We offer Z-Meters - devices for examination of performance and reliability parameters of thermoelectric cooler, developed by RMT company.  The RMT's Z-Meters have extended capabilities, many useful functions for fast and accurate testing of various types of thermoelectric coolers.

The following parameters of thermoelectric coolers can be measured:

  1. AC Resistance (R) 

  2. Thermoelectric Figure-of-Merit (Z) 

  3. Maximum Temperature Difference (dTmax)

  4. Time Constant of TE Coolers (t)

Z-Meter - Thermoelectric Coolers Measuring Tool

The Z parameter and dTmax result from  Harman method concept. Advanced technique developed in RMT allows precise characterization of single-stage and two-stage TE coolers, measurement of AC resistance and time constant in a wide range.
Additionally, it is possible to evaluate quality of three or more-stage TE coolers by the measurement of electrical resistance and time constant.

Advantages

  1. Testing of single stage and multi-stage     thermoelectric coolers

  2. Performance of TE coolers integrated into devices (photodetectors, lasers and other TE cooled parts)

  3. Time constant measurement

  4. Single point (DX4065) and Multi-point (DX4165) device models

Features

  1. Current adjustable in a range 0...200 mA 

  2. Measurement at direct and reversed current

  3. Results normalization to standard temperatures

  4. Correction coefficients to Z value

  5. Compact design

  6. Low power consumption 

Device Options

  1. Single position Device DX4065 with USB communication port.

  2. New Series DX4165. Multipoint device, up to ten (10) TE coolers testing simultaneously.

Download DX4065 manual

Download DX4165 manual

Back to ProductsProducts.html

© TEC Microsystems GmbH 2010